AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000
Page 348 01/2011 Installation and activation
6.2.8 Resetting the manufacturer's password (in case of loss)
The default manufacturer's password can be reset if the user loses the manufacturer's access code
defined from the menu
TELEPHONY/SYSTEM/Configuration/Users/System accounts (if the user
had chosen its modification).
This may become necessary if the user loses or forgets this manufacturer's access code.
Rappel : The manufacturer's access code may be modified to reinforce system security.
In this case, neither the user nor the manufacturer (AASTRA) will have access to
AMP in manufacturer mode (see the document AMT_PTD_PBX_0080 for
information about password management).
Preliminary operation
Contact AASTRA's customer service to obtain the values Enter Identifier and Enter Key which will
be required during the procedure described below. You also need to provide the (i-Button) ID
number. This number will be provided to AASTRA in order to generate the values
Enter Identifier
and Enter Key.
Procedure
On the PC connected to the COM port
• Open a Hyperterminal window and configure the connection as follows:
- Bits per second: 115200 bits/s
- Data bits: 8
- Parity: none
- Stop bits: 1
- Flow control: None
• Power on the cabinet and follow the start-up progress on the PC:
• Upon display of "Identification starting"
•Press Ctrl + I
• The screen then displays the different configuration modes.
• Select "P" mode to enter the pre-configuration menus.
• In the next screen, enter the values
Enter Identifier and Enter Key provided by