Page 364 01/2011 Installation and activation
• Back up the customer configuration.
• Power off the main cabinet.
• Remove the upper cover of the main cabinet to insert the internal ribbon cable required
for extension.
• Remove the internal rear plate to allow the connection of the expansion ribbon cable.
• Connect the expansion ribbon cable (reference: BHR0129A).
• Screw on the expansion connector to the rear side of the main cabinet, using only the
two screws provided with the kit.
• Reinstall the rear internal plate.
• Put back the upper cover of the main cabinet.
• Install the expansion cabinet cards.
• Install the expansion cabinet and connect it to earth (see Sections 3 and 6.2.5).
• Connect the expansion cabinet to the main cabinet using the connection cable
(BHT8212A).
• Install the cable on the front panel of the expansion cabinet cards.
• Install the battery cabinet if available.
• Connect the two battery leads.
• Make sure the polarity is correct.
• Connect the battery cable to the “48 V BATT.” connector of the power supply module
located at the back of the cabinet on an AXS, AXS12 or AXS6 iPBX.
• Connect one end of the mains cable to the power supply module(s) of the expansion
cabinet and the other end to a grounded mains power point.
• Power on the iPBX (expansion cabinets first then the main cabinet).
• Check that the yellow and green indicators on the front panel of the cabinet sub-
assemblies are lit, and that no red indicator is on (refer to Sections 4.3 to 4.14 to check
that the operating conditions shown by the indicators are correct).
• From the AMP, check that the software has detected the cabinet expansion.
• Configure the new expansion cabinet equipment.
• Configure the new expansion cabinet equipment
(see AMP operating manual).
• Save the configuration.