Installation and Maintenance Manual - Aastra 5000 AMT/PTD/PBX/0058/4/6/EN
Installation and activation 01/2011 Page 383
Configuring the Aastra X series system
• Assign a DID number.
Modem configuration
• Automatic: controlled by the Aastra X Series Gateway
Hayes commands for analogue US ROBOTICS modem configuration
In case of ppp remote maintenance connection problem on a modem, check your
modem's register configuration.
Below is the recommended modem register configuration.
• atS0= 2 off-hook after 2 seconds
• &b1=115200 serial port throughput
To see the register bases, type either at&v or at&i4.
Attention : Do not forget to back up using at&w
Configuring the PPP connection
In Control Panel
• Click " Network connections ".
• Select Create a new connection.
•In New connection wizard, clickNext.
• Tick successively the boxes indicated below:
-In the Network connection type screen, tick Connection to company network.
- Click Next.
-In the Network connectionscreen, tick Remote access connection.
- Click Next.
- Choose the modem type on the list proposed.
- Click Next.
-In the Connection name screen, fill in the Company name field.
- Click Next.
- In the screen Enter the phone number to dial , enter the call number for this
connection via modem.
- Click Next.
-In the Connection availability screen, tick All users.
- Click Next.
The PPP configuration has been completed.
In the " Start " menu, " Parameters " tab, start the connection to the PBX.