EasyManua.ls Logo

ABB CRB 15000 - Page 129

ABB CRB 15000
1096 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Modify the Cyclic Brake Check settings
The Cyclic Brake Check functionality is active by default. It can be modified and
deactivated.
xx2100000717
Viewing the configuration report
The configuration report is available both on the FlexPendant and on the controller.
It can be viewed from the Context menu.
Loading and exporting a safety configuration
An existing safety configuration on the FlexPendant can be exported from the
Context menu, Save Configuration To File. It is also possible to load a safety
configuration from a file.
Validate the safety configuration
DANGER
A SafeMove configuration must always be validated to verify that the desired
safety is achieved. If no validation is performed, or the validation is inadequate,
the configuration cannot be relied on for personal safety.
Each new or modified safety configuration must be validated before running in
production. The validation should verify that the following is configured correctly:
All I/O settings and signals used for safety interlocking including connected
functionality
All Stop configuration functions
Continues on next page
Product manual - CRB 15000 129
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
3 Installation and commissioning
3.6.3 The SafeMove configurator app on FlexPendant
Continued

Table of Contents

Related product manuals