Connecting the base cabling
NoteAction
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section The
unit is sensitive to ESD on page 53.
1
xx2100000405
Reconnect the connectors to the drive board.
D1.X1 to X1
D1.DC+ to DC+
D1.DC- to Ground
2
xx2100000426
Connect the connectors to each other and snap
them to the cable holders.
J1.DC+ to J1.DC+
J1.DC- to J1.DC-
J1.CS to J1.CS
J1.CP to J1.CP
3
Hex socket head cap screw: M3x6
(1 pcs).
Secure the cables for functional earth and protect-
ive earth with a screw.
4
Tightening torque: 0.8 Nm.
xx2100000425
Continues on next page
214 Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the base cabling
Continued