Removing the joint cabling (-10/1.52 and -12/1.27)
Use these procedures to remove the joint-2 cabling.
Preparations before removing the cabling
NoteAction
xx2100000044
Jog the robot to the specified position: xxx
Axis 1:
Axis 2: (home position)
Axis 3: +60°
Axis 4:
Axis 5: -90°
Axis 6: No significance.
CAUTION
Jog the axis on which the joint unit is to be re-
placed to home position, to achieve correct cable
routing during replacement of the joint unit.
1
CAUTION
Turn off all supplies for electrical power to the
robot, before starting the repair work.
2
Removing the lower arm covers (-10/1.52 and -12/1.27)
NoteAction
CAUTION
Make sure that all supplies for electrical power
are turned off.
1
xx2300000812
Remove the lower cover of lower arm by removing
the screws.
2
Continues on next page