NoteAction
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (1 pcs).
Connect the functional earth cable with the screw.3
Tightening torque: 0.8 Nm
xx2000001936
Removing the lower arm covers (-10/1.52 and -12/1.27)
NoteAction
CAUTION
Make sure that all supplies for electrical power
are turned off.
1
xx2300000812
Remove the lower cover of lower arm by removing
the screws.
2
xx2300000813
Remove the lower inner cover by removing the
screws.
3
Continues on next page
Product manual - CRB 15000 341
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.3 Replacing the axis-2 cabling
Continued