NoteArticle numberConsumable
Axis-4 cover, used for CRB
15000-5/0.95.
Replace if damaged.
3HAC061327-051O-ring
Axis-4 cover, used for CRB
15000-10/1.52 and CRB 15000-
12/1.27.
Replace if damaged.
3HAC061327-051O-ring
Tubular cover, used for CRB
15000-5/0.95.
Replace if damaged.
3HAC061327-043O-ring
Tubular cover, upper, used for
CRB 15000-10/1.52 and CRB
15000-12/1.27.
Replace if damaged.
3HAB3772-166O-ring
Tubular cover, lower, used for
CRB 15000-10/1.52 and CRB
15000-12/1.27.
Replace if damaged.
3HAC061327-076O-ring
Arm-side interface
Replace if damaged.
3HAC061327-051O-ring
Shell Gadus S23HAC042536-001Grease
M3x12 12.9 Lafre
2C2B/FC6.9+PrO-COat111, with
NYPLAS glue
For tubular cover of CRB 15000-
5/0.95.
Always use new screws.
If ordering a new axis-4 or axis-5
joint unit spare part, new screws
for the tubular cover are included.
3HAB3413-312Flange socket head screw with
glue
Isopropanol-Cleaning agent
Loctite 574-Flange sealant
Removing the joint cabling
Use these procedures to remove the joint-5 cabling.
Preparations before removing the cabling
NoteAction
Jog the robot to the specified position: xxx
• Axis 1: No significance.
• Axis 2: No significance.
• Axis 3: No significance.
• Axis 4: No significance.
• Axis 5: 0° (home position)
• Axis 6: No significance.
1
CAUTION
Turn off all supplies for electrical power to the
robot, before starting the repair work.
2
Continues on next page
Product manual - CRB 15000 419
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.3.6 Replacing the axis-5 cabling
Continued