NoteAction
Hex socket head cap flange screw:
M4x25 12.9 Lafre
2C2B/FC6.9+PrO-COat111 (16 pcs)
Secure the lower arm to the swing with all attach-
ment screws but two.
Pre-tighten the screws crosswise firstly.
CAUTION
Do not mix the flange screws used for CRB 15000-
5/0.95 and the threaded screws used for CRB
15000-10/1.52 and CRB 15000-12/1.27. Always
use washers together with the threaded screws
for CRB 15000-10/1.52 and CRB 15000-12/1.27.
Illustration is for reference only.
5
xx2000001940
Hex socket head cap flange screw:
M4x25 12.9 Lafre
2C2B/FC6.9+PrO-COat111 (16 pcs)
Remove the guide pins and fasten the remaining
two screws.
CAUTION
Do not mix the flange screws used for CRB 15000-
5/0.95 and the threaded screws used for CRB
15000-10/1.52 and CRB 15000-12/1.27. Always
use washers together with the threaded screws
for CRB 15000-10/1.52 and CRB 15000-12/1.27.
Illustration is for reference only.
6
xx2000001951
Tightening torque: 4.6 NmTorque tighten all screws crosswise.7
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (4 pcs).
Refit the cable bracket with four screws.8
Tightening torque: 0.8 Nm
xx2000001939
Continues on next page