NoteAction
Example of CRB 15000-5/0.95,
similar to CRB 15000-10/1.52 and
CRB 15000-12/1.27.
Lift the upper and lower arm assembly to mount-
ing position and slide it onto the guide pins.
3
xx2000001941
Hex socket head cap screw: M5x30
12.9 Lafre 2C2B/FC6.9, 16 pcs
Secure the lower arm to the swing with all screws
and washers but two.
4
xx2300001022
Pre-tighten the screws crosswise firstly.
CAUTION
Do not mix the flange screws used for CRB 15000-
5/0.95 and the threaded screws used for CRB
15000-10/1.52 and CRB 15000-12/1.27. Always
use washers together with the threaded screws
for CRB 15000-10/1.52 and CRB 15000-12/1.27.
Illustration is for reference only.
Hex socket head cap screw: M5x30
12.9 Lafre 2C2B/FC6.9, 16 pcs
Remove the guide pins and fasten the remaining
two screws and washers.
CAUTION
Do not mix the flange screws used for CRB 15000-
5/0.95 and the threaded screws used for CRB
15000-10/1.52 and CRB 15000-12/1.27. Always
use washers together with the threaded screws
for CRB 15000-10/1.52 and CRB 15000-12/1.27.
Illustration is for reference only.
5
xx2300001023
Tightening torque: 8.2 NmTorque tighten all screws crosswise.6
Continues on next page
900 Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.6.4 Replacing the axis-2 joint unit (CRB 15000-10/1.52 and CRB 15000-12/1.27)
Continued