NoteAction
xx2000002130
Remove the remaining attachment screws.2
Press the tilt out of position using two of the pre-
vious attachment screws as removal tools.
3
xx2000002131
Remove the tilt from the tubular.
Assist the cabling to be removed while lifting away
the complete tilt.
Place the tilt on a workbench.
4
Removing the tool flange
NoteAction
xx2000002155
Remove the tool flange screws and washers.1
CAUTION
Valid for CRB 15000-5/0.95
There is cabling connected between the cover
and the joint unit drive board.
Open the cover with care to avoid damage to the
cabling or the connector(s).
Do not leave the cover in location without being
secured with the attachment screws.
2
Continues on next page
988 Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.6.7 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued