NoteAction
xx2000002166
Press the adapter out of position by using two of
the attachment screws as removal tools.
2
xx2000002167
Remove the tool flange adapter.3
Removing the arm-side interface
NoteAction
CAUTION
Make sure that all supplies for electrical power
are turned off.
1
CAUTION
There is cabling connected between the arm-side
interface and the joint unit drive board.
Open the arm-side interface with care to avoid
damage to the cabling or the connector(s).
Do not leave the arm-side interface in location
without being secured with the attachment screws.
2
xx2000002550
Remove the attachment screws.3
Continues on next page
990 Product manual - CRB 15000
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.