NoteAction
Guide pin, M3x110: 3HAC077787-
001
Fit two guide pins to the axis-6 joint unit.3
Always use guide pins in pairs.
For joint units on axes 4, 5 and 6.
xx2100000328
xx2100000329
Remove the remaining attachment screws.
Use two screws as press out screws in the upcom-
ing step, then dispose all screws.
New screws are included in the spare part delivery
of the joint unit.
4
xx2100000330
Press the joint unit out of position using two of
the previous attachment screws as removal tools.
5
Continues on next page
Product manual - CRB 15000 993
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.6.7 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued