TweezersDisconnect the connectors from the drive board.
D6.X1
D6.DC+
D6.DC-
D6.X4
D6.X2
D6.X5
CAUTION
Use tweezers to unlock connectors and pull them
off.
4
xx2000002164
Removing the axis-6 joint unit
NoteAction
Lifting aid: 3HAC077789-001Fit the lifting aid to the joint unit, on the torque
sensor side.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
1
Screws: M3x12 (4 pcs)
xx2000002168
Position shown in the figure shows
axis 5 jogged to +20°, which is a
more convenient position when re-
placing only the axis-6 joint unit.
xx2000002170
Remove two attachment screws.
Dispose the screws.
New screws are included in the spare part delivery
of the joint unit.
2
Position shown in the figure shows
axis 5 jogged to +20°, which is a
more convenient position when re-
placing only the axis-6 joint unit.