Refitting the controller covers
Preparations
Info/illustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 31.
1
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 47.
2
Refitting the right side cover
Info/illustrationAction
xx1800000469
Place the right side cover into the guide
holes and press it into the locking posi-
tion.
1
Screws: Torx, countersunk screw M4x10 (6
pcs)
xx1800000470
Fasten with screws.2
Continues on next page
Product manual - OmniCore C30 227
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.1 Opening the robot controller
Continued

Table of Contents