Concluding procedure
Note/IllustrationAction
Refitting the controller covers on page 227.Refit the covers.1
Restoring the hardware settings on page 356.Restore the hardware settings.2
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 212.
3
Restoring the hardware settings
The controller hardware settings include information such as controller type and
serial number. When the main computer has been replaced, the serial number
must be restored before any software can be installed, or any licences can be
imported.
Note
When replacing the main computer, both the serial number and licences are lost.
The serial number must be restored as described below. Licences however, can
either be restored automatically when the RobotWare system is installed, or
manually through Manage Licences in RobotWare Installation Utilities.
Note/IllustrationAction
Download the hardware information file
(hwsettings.rsf) from MyABB, or from a
previous system backup.
1
xx1900000110
Access the RobotWare Installation Utilit-
ies.
2
Tap Advanced, and then Restore Hard-
ware Settings.
3
The Restore Hardware Settings window
is displayed.
4
Follow the instructions and tap Next to
proceed.
Carefully read the information and then
check all boxes to confirm that you agree
with the ABB conditions. Tap Next to
proceed.
5
Continues on next page
356 Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.9 Replacing the main computer
Continued