Note/IllustrationAction
xx1900001200
Remove the screws on the bracket.2
Loosen the screw and disconnect:
• SMB - K6.X4, K6.X5
3
Removing the power unit
Note/IllustrationAction
Disconnect:
• A1.X13 - K2.X10
• A1.X9 - K2.X4
• A1.X4 - T4.X5
31
• A1.X4 - X1
32
• A1.X5 - T4.X1
• A1.X12 - T4.X3
• A1.X1 - Incoming mains (X0)
• A1.X6 - T2.X1
33
• A1.X6 - X107
34
• (Option) A1.X7 - T5.X1
1
Open the velcro strap for the main har-
ness. Lift the harness gently out to make
room for the power unit to be removed.
2
31
Not available for CRB 15000 controller.
32
Only used for CRB 15000 controller.
33
Not available for CRB 15000 controller.
34
Only used for CRB 15000 controller.
Continues on next page
360 Product manual - OmniCore C30
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.2.10 Replacing the power unit
Continued