EasyManua.ls Logo

ABB OmniCore C30 - Page 421

ABB OmniCore C30
606 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note/IllustrationAction
Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 47.
2
Screws: Torx, countersunk screw M4x10 (4
pcs)
xx1800000730
Insert the motor connector into the front
panel from inner side of the cabinet and
fasten it with the screws.
3
Reconnect:
T4.X7, T4.X8, T4.X9
X1 - K2.X7 & X22
Two ground cables which con-
nects on the left side of the cabin-
et frame.
4
Secure the motor connector cables with
the velcro on the frame of the cabinet.
Tip
Use the same position as from removing
the motor connector.
5
Continues on next page
Product manual - OmniCore C30 421
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.2.1 Replacing the motor connector
Continued

Table of Contents

Related product manuals