Location of wrist strap button:
xx1800000683
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 47.
2
Screws: Torx, countersunk screw M4x10 (4
pcs)
xx1800000730
Insert the motor connector into the front
panel from inner side of the cabinet and
fasten it with the screws.
3
Reconnect:
• T4.X7, T4.X8, T4.X9
• X1 - K2.X7 & X22
• Two ground cables which con-
nects on the left side of the cabin-
et frame.
4
Secure the motor connector cables with
the velcro on the frame of the cabinet.
Tip
Use the same position as from removing
the motor connector.
5
Continues on next page
Product manual - OmniCore C30 421
3HAC060860-001 Revision: P
© Copyright 2019-2022 ABB. All rights reserved.
5 Repair
5.3.2.1 Replacing the motor connector
Continued