A protective stop device needs to be connected to the protective stop input. See
example below.
16
1
5
17
8
10
9
7
18
A2.K5.X15
0V_IO_EXT
24V_CH1_EXT
AS_CH1_P
AS_CH1_N
0V_IO_EXT
24V_CH2_EXT
Customer provided
protec!ve stop device
AS_CH2_P
AS_CH2_N
xx2300000993
The protective stop input can be powered from an external power supply:
Customer_24V_CH1
Customer_24V_CH2
Customer_0V_CH1
Customer_0V_CH2
Customer provided power
0V_IO_EXT
24V_CH1_EXT
0V_IO_EXT
24V_CH2_EXT
AS_CH1_P
AS_CH1_N
AS_CH2_P
AS_CH2_N
16
15
17
8
10
9
7
18
Customer provided
protec!ve stop device
A2.K5.X15
xx2300000994
Continues on next page
Product manual - OmniCore V250XT Type B 101
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
3 Installation and commissioning
3.5.9 Descriptions for connectors
Continued