Note/illustrationAction
Connecting incoming mains and protective
earth to the controller on page 84.
Connect incoming mains from an external
earth fault protection.
3
Fit the cable trough the cable gland (A)
and tighten.
4
Strip the insulation on the mains cable
long enough to reach the incoming mains
switch (B).
5
xx2100002287
Connect protective earth to one of the
two screws.
6
Note
Use cable lugs in the connection.
Tightening torque: 5 Nm
Route the phase wires through the pipe
up to the incoming mains switch (B).
7
See circuit diagram.Connect the wires to the incoming mains
switch (B).
8
Refit protection on the incoming mains
switch (B).
9
152 Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.9 Installing the mains connections cable
Continued