Note/IllustrationAction
Screws: Torx pan head screw M4x8 (4 pcs)Refit the cable entry frame to the enclos-
ure wall and secure with the screws.
6
Tightening torque: 1.5 Nm.
xx1900002332
Refitting the cable grommet assembly
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
2
xx2200001817
Continues on next page
310 Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
5 Repair
5.3.4 Replacing the cable grommet assembly
Continued