Loading...
Refitting the Ethernet outlet connector with cable
Refitting the Ethernet outlet connector with cable
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
2
Insert the Ethernet outlet connector with
cable into the cover from inner side of
the cabinet.
3
xx2100000852
Secure it with the locking ring.4
Reconnect any connectors disconnected
at removal.
5
Secure the Ethernet outlet connector with
cables with the clips on the cabinet.
Tip
Use the same position as from removing
the harness ETH outlet with cable.
6
Concluding procedure
Note/IllustrationAction
Closing the door on page 185.Close the door.1
Continues on next page
316 Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
5 Repair
5.3.5 Replacing the Ethernet outlet connector with cable
Continued

Table of Contents