EasyManua.ls Logo

ABB OmniCore V250XT Type B - Page 320

ABB OmniCore V250XT Type B
468 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removing the LED indicator
Note/IllustrationAction
xx1900001926
Loose the attachment screws locking the
cable.
1
Remove the terminals (X1&X2) of the
cable from the lamp.
2
Turn the MON_LAMP screw anti-clock-
wise to remove the screw.
3
Take the LED indicator out.4
Refitting the LED indicator
Refitting the LED indicator
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
2
Insert the LED indicator into the cover
from outer side of the door and the screw
from inner side and screw them up.
3
Continues on next page
320 Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
5 Repair
5.3.6 Replacing the LED indicator
Continued