Troubleshooting procedure
The troubleshooting table is supposed to be used as a detailed instruction together
with the troubleshooting flowchart.
NoteAction
Make sure that the power unit is operational.Make sure the power has been off
for more than 10 seconds.
1
Wait at least 1 min after power-on.
Power on the controller. Check the
MODULE STATUS LED on the
power unit.
If the MODULE STATUS LED is:
Off: The power unit is in the power off
state. Proceed with step 2.
Red, steady: Internal error. Proceed with
step 7.
Flashing red (~ 1Hz): Firmware error or
self-test failure. The power unit may be
faulty, see Replacing the power unit on
page 244.
Flashing green (~ 1Hz): Internal commu-
nication error or 24V_SYS is missing.
Proceed with step 11.
Steady green but DC-BUS High Voltage
LED is off: Proceed with step 12.
Verify that the input to A1.X1 is 380-480V AC.
If AC_IN is between 380-480V AC, pro-
ceed with step 5.
If AC_IN is is abnormal, there is an issue
with A1.X1. Proceed with step 3.
Verify AC_IN.2
If the connection seems OK, proceed with step
5.
Check the connector at A1.X1 (AC
input). Make sure that the power
cables are connected properly at
both ends.
3
If there is a problem with the connection, pro-
ceed with step 4.
If the connection seems OK, proceed with step
5.
Replace AC input cable A1.X1.4
If there is a problem with the connection, check
power source and incoming mains. Make sure
that AC_IN is OK.
Verify that the input to A1.X6 is 25.2 VDC +/-
5%.
If the measured voltage is normal and
MODULE STATUS LED is green, pro-
ceed with step 7.
If the measured voltage is normal and
MODULE STATUS LED is off, the unit
may be faulty, see Replacing the power
unit on page 244.
If the measured voltage is abnormal,
proceed with step 6.
Measure the 24V_TRUNK at con-
nector A1.X6.
5
Continues on next page
Product manual - OmniCore V250XT Type B 387
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
7 Troubleshooting
7.3.5 Troubleshooting the power unit
Continued

Table of Contents