Dimensions
ValueParameter
650 mmWidth
480 mmDepth
960 mmHeight
Weight
WeightController
85 kgOmniCore V250XT Type B
Note
The weight does not include any mounting kits fitted on the controller.
Transportation and storage conditions
ValueParameter
-40°C (-40°F)Minimum ambient temperature
+55°C (+131°F)Maximum ambient temperature
+70°C (+158°F)Maximum ambient temperature (less than 24
hrs)
In accordance with ETSI EN 300 019-2-2 /
Environmental class 2.3
Shock and Vibration
(No severity reduction for horizontal axes)
Max. 5 g = 50 m/s
2
(11 ms)
After storage, the operating conditions inside the controller must be met for at least
6 hours before switching on the controller (see Operating conditions on page 39).
The robot controller shall be stored according to its IP classification (IP54), that is,
indoors, in an environment that is dry and dust-free. In addition, wind, temperature
fluctuations, and condensation shall be avoided.
See also Product specification - OmniCore V line.
Operating conditions
The table shows the allowed operating conditions for the controller.
ValueParameter
+5°C (+41°F)Minimum ambient temperature
+45°C (+113°F)Maximum ambient temperature
2,000 mMaximum ambient altitude
In accordance with ETSI EN 300 019-2-3 /
Environmental class 3.5 (3M5)
Shock and Vibration
(Random vibration)
Continues on next page
Product manual - OmniCore V250XT Type B 39
3HAC087112-001 Revision: A