NoteAction
Measure the resistance between bleeder con-
nector (X10.1 and X10.2)
• If the connection is OK, proceed with
step 11.
• If there is a problem with the connection,
repair the connection and start over.
• If the resistance of bleeder is greater
than 20 ohm or less than 10 ohm, replace
the bleeder. See Replacing the break
resistor bleeder on page 284.
Check the bleeder connection at
X10.
CAUTION
Before measuring the bleeder res-
istance, do the following:
• Shut down the power and
wait 1 minute.
• Disconnect X10.
10
See Replacing the power unit on page 244.The unit may be faulty. Replace the
power unit.
11
Product manual - OmniCore V250XT Type B 395
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
7 Troubleshooting
7.3.6 Troubleshooting the HVLP power unit (DSQC3072)
Continued