Parameters 137
b13: Spare DI8
b14: Spare DI9
b15: Spare DI10
204.06 PLC watchdog read PLC reads this parameter and copies the value to PLC
watchdog write parameter. This parameter also has the
reboot/error return acknowledgement signal in bit 8. It
means that PLC has noticed the reboot or the error
acknowledgement signal.
-/ Real
0...65535 1 = 1
204.101 Control section humidity Defines the humidity measured from control section. -/ Real
0...65535 1 = 1
204.102 Spare AI3 Defines the spare analog input AI3 of the PLC. -/ Real
0...65535 1 = 1
204.103 M1 DC section humidity Defines the cabinet humidity measurement for power
module 1 from the DC section.
-/ Real
0...65535 1 = 1
204.104 M1 AC section humidity Defines the humidity of cabinet measured in the AC
section.
-/ Real
0...65535 1 = 1
204.105 M1 AC section
temperature
Defines raw data of LCL section temperature
measurement for power module 1.
-/ Real
0...65535 1 = 1
204.106 M1 AC section
temperature
Defines raw data of AC section temperature
measurement for power module 1.
-/ Real
0...65535 1 = 1
204.107 M1 DC section
temperature
Defines raw data of DC section temperature
measurement for power module 1.
-/ Real
0...65535 1 = 1
204.108 M2 main air channel
temperature
Defines raw data of main air channel temperature
measurement for power module 2.
-/ Real
0...65535 1 = 1
204.109 M1 main air channel
temperature
Defines raw data of main air channel temperature
measurement for power module 1.
-/ Real
0...65535 1 = 1
204.110 M2 DC section humidity Defines the cabinet humidity of power module 2,
measured from the DC section.
-/ Real
0...65535 1 = 1
204.111 M2 AC section humidity Defines the cabinet humidity of power module 2,
measured from AC section.
-/ Real
0...65535 1 = 1
204.112 M2 LCL section
temperature
Defines raw data of LCL section temperature
measurement for power module 2.
-/ Real
0...65535 1 = 1
204.113 M2 AC section
temperature
Defines raw data of AC section temperature
measurement for power module 2.
-/ Real
0...65535 1 = 1
204.114 M2 DC section
temperature
Defines raw data of DC section temperature
measurement for power module 2.
-/ Real
No. Name/Value Description Def/
FbEq16/32

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB PVS980-58 and is the answer not in the manual?

ABB PVS980-58 Specifications

General IconGeneral
BrandABB
ModelPVS980-58
CategoryInverter
LanguageEnglish

Related product manuals