Troubleshooting 171
57629
(0xe11
d)
PLC link fault Internal PLC communication
failure,
inverter is stopped.
Reboot aux. power from the
inverter twice. If problem
persists, contact your local
FIMER representative.
57630
(0xe11
e)
DC input reverse
connected
Negative voltage detected in DC
input. DC input positive and
negative voltages are connected in
reverse order.
Check connection of DC
positive and negative poles.
57631
(0xe11f
)
Nominal voltage out of
range
Nominal grid voltage has
exceeded limits.
Check parameter 135.02
Nominal LL voltage
57632
(0xe12
0)
No country code
selected
No country or grid code is selected Select country or grid code with
parameter 135.01 Grid code.
57633
(0xe12
1)
AC Breakers AC breakers are not closed within
the expected time.
Check AC breaker connections.
57634
(0xe12
2)
AC breaker manually
opened
Inverter opened AC breakers after
receiving a user command.
Close breakers by user
command with parameter
214.02 Manual AC breaker
control before inverter can start.
Note: Parameter 214.02 is
visible only with Expert level
access.
Contact you local FIMER
representative.
57635
(0xe12
3)
External warning 1 Customer IO external warning 1 Customer specific warning,
check parameter group 176
Customer IOs.
57636
(0xe12
4)
External warning 2 Customer IO external warning 2 Customer specific warning,
check parameter group 176
Customer IOs.
57637
(0xe12
5)
External warning 3 Customer IO external warning 3 Customer specific warning,
check parameter group 176
Customer IOs.
57639
(0xe12
7)
Wrong PLC inverter
type
PLC and BCON softwares are not
for same inverter (PVS980 /
PVS800)
Check software version of the
PLC or the inverter Firmware
version.
57640
(0xe12
8)
Wrong PLC type PLC hardware differs from
parametrization. PLC XC / eCo
type is not correct.
Check parameters 206.108
Option C184 and 206.109
Option C129. Those
parameters set XC PLC model.
Contact you local FIMER
representative.
57641
(0xe12
9)
MV transformer gas
discharge warning
Medium voltage transformer gas
discharge input triggered.
Check parameter group 177 MV
Station.
Code Warning Cause What to do