Since the headlight bulb gets extremely hot, keep
flammable products and your hands away from the
bulb until it has cooled down.
2.Inspect bulb for continuity with the multi-meter, If discontinuity
Replace the bulb.
NOTE: Before checking for continuity, set the multi-meter
to “0” and to the “Ω∗1” range.
3.Connect the tester positive probe to terminal
and the tester
negative probe to terminal
, and check the continuity.
4.Connect the tester positive probe to terminal
and the tester
negative probe to terminal
, and check the continuity.
5.If either of the readings indicates no continuity, replace the bulb.
BULB SOCKETS INSPECTION
1. Install a good bulb into the bulb socket.
2. Connect the multi-meter probes to the respective leads of the bulb
socket.
3. Check the bulb socket for continuity. If any of the readings indicate
no continuity, replace the bulb socket.