8. Operation Screens
8-131
(*) About interval
The interval corresponds to the number of weldings. Since it depends on the
number from the last save, the number of saves changes depending on the
OUT OF LIMIT OPERATION setting.
INTERVAL setting 1 1 3 3
OUT OF LIMIT OPERATION setting ON OFF ON OFF
1st welding OK - Save - -
2nd welding OK - Save - -
3rd welding OK - Save Save Save
4th welding OK - Save - -
5th welding NG Save Save Save -
6th welding OK - Save - Save
7th welding OK - Save - -
8th welding OK - Save Save -
(3) OUT OF LIMIT OPERATION
Select ON/OFF to specify whether to save only in the event of Upper limit error,
Lower limit error, Overrange error, Impulse error, or Parity error.
ON: Saves irrespective of interval in the event of an error.
OFF: Saves each interval irrespective of errors.
Saves at intervals set for INTERVAL when normal. Saves at the time of an
error occurrence when abnormal.