EasyManua.ls Logo

Amada WELD CHECKER MM-400A - Page 192

Amada WELD CHECKER MM-400A
328 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MM-400A
9. Measurement
9-11
12) To display the waveforms of displacement, set those items in WAVEFORM 1 to
4.
13) Touch the MENU key to select MEASUREMENT or WAVEFORM.
14) Select a schedule number to measure.
When setting by the touch panel, set a schedule number to measure in
SCH.#without inputting a signal to the external input (SCH1 to 64).
When selecting by the external input (SCH1 to 64), input a signal in the
external input (SCH1 to 64). (Refer to (1) (2) in Chapter 10.)
15) Touch PROG to change it to MEAS, putting the MM-400A into wait state until
measurement starts (the signal selected as trigger is input).
16) When the trigger signal is input to the MM-400A, the [TRIGGER] lamp lights
up and measurement starts. Confirm the measurement results on the
MEASUREMENT and WAVEFORM screens. You can also print measured
values and waveforms from the PRINT screen, as necessary. (For more
information, refer to (1) and (2) in Chapter 8.)

Table of Contents