MM-400A
8. Operation Screens
8-46
• FORCE ALL CYCLE
Writes force all cycles in the USB memory. Available only for the
force/displacement-equipped specification.
The filenames are “force_allcycle-0.csv” to “force_allcycle-1000.csv.” After
1000, the filename returns to 0. The file is overwritten.
“¥force_allcycle” folder is created by the SAVE key and
“¥force_allcycle_in_meas” folder is created by automatic saving for every
interval.
When SEAM is selected for MODE in the SYSTEM SETUP (1) screen, no
writing in the USB memory is made.
• HISTORY
Writes history selected in HISTORY AREA (20**/**/** to 20**/**/**) among
measured values saved in the HISTORY screen in the USB memory. To
save, first select this item, and then touch SAVE.
The filenames are “hist_measure-0.csv” to “hist_measure-1000.csv.” After
1000, the filename returns to 0. The file is overwritten. “¥hist_measure”
folder is created.
When SEAM is selected for MODE in the SYSTEM SETUP (1) screen, no
writing in the USB memory is made.
• HISTORY OUT OF LIM
Writes history selected in HISTORY AREA (20**/**/** to 20**/**/**) among
measured values with Upper limit error, Lower limit error, Overrange error,
Impulse error, or Parity error saved in the HISTORY screen in the USB
memory. To save, first select this item and touch SAVE.
The filenames are “hist_error-0.csv” to “hist_error-1000.csv.” After 1000, the
filename returns to 0. The file is overwritten. “¥hist_error” folder is created.
When SEAM is selected for MODE in the SYSTEM SETUP (1) screen, no
writing in the USB memory is made.
• SCHEDULE
Writes/Reads the schedule data in/from the USB memory. At writing, the
information selected among schedules 1 to 127 is written. At reading, only
the selected schedule is read. Also, set the file number (01 to 10) to read
from or write in the schedule data. The schedule data can be backed up and
copied to other MM-400A.
“¥sch_set” folder is created, and “¥FileNo_01” to “¥FileNo_10” folders are
created in a lower hierarchy for each file number.
(Note) Before reading the schedule data, change the decimal point setting to
the same setting as that set when saved it. (Refer to “(6) DECIMAL POINT
RANGE.”) When the decimal point has not been changed from the initial
setting, it can be read with the present setting. The initial setting of decimal
point is “.”.
• SCREEN
Writes screen image prior to the USB screen in the USB memory. To write in
the USB memory, first display the screen to write. Then, return to the USB
screen by MENU and touch SAVE.
The data format is BITMAP. The filenames are “screen_bmp-0.bmp” to
“screen_bmp-1000.bmp.” After 1000, the filename returns to 0. The file is
overwritten.
“¥screen_bmp” folder is created.
• ENVELOPE
Writes the envelope data from the USB memory or reads an optionally
created envelope data from the USB memory. Create a folder named
“¥env_set” in the USB memory and store the envelope data in the folder.
The filename depends on schedule number, envelope number and
waveform type, for example, “Env01_1_C.csv.” Refer to “f-4. How to set the
envelope reference waveform and the determination range, .”
When SEAM is selected for MODE in the SYSTEM SETUP (1) screen, no
writing in the USB memory is made.