EasyManua.ls Logo

Aventics Marex 3D - Mounting the Heading Sensor

Aventics Marex 3D
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
AVENTICS | Marex 3D | R417003094–BDL–001–AA 37
English
lengths. See also chapter 1.2, Required and additional
documentation, on page 1.2.
O Observe project-specific documentation if applicable.
O Refer to the manual "MarexOSII/III, Devices and
adjustments" for information on installing and starting up
MarexOS standard components.
O Observe corresponding instructions for Marex ECS if
applicable.
5.2 Mounting the heading sensor
The heading sensor can be mounted in any installation position.
Special attention must be paid to its installation site:
W The heading sensor must have a clear view of the sky in all
directions.
W To prevent interferences to the compass signal, the sensor
must be mounted 1.5 m
above a metal hull/deck
away from any structures or equipment containing
ferrous metals
away from anything that creates a magnetic field
O Mount the sensor:
1 m away from any VHF radio
4 m away from any antenna (MF/HF)
3 m away from loop antenna
3 m away from radar and not within its beam
5 m away from INMARSAT and not within its beam
3D_manual_R417003094_DE_EN.book Seite 37 Freitag, 30. November 2018 11:36 11

Table of Contents

Other manuals for Aventics Marex 3D