WORD # WORD NAME Data Type
179-228 Command Response Data 100 Byte Array
229-239 reserved 16-bit integer
NOTE: If the inspection contains more than five sensors, the sensor after the fifth one will not be on
the map.
Table 15: Area Sensor Type ID = 2
Sensor Specific Data Data Size
Area Count 32- bit integer
Area Range Min 32- bit integer
Area Range Max 32- bit integer
Table 16: Blemish Sensor Type ID = 3
Sensor Specific Data Sensor Location
Blemish Count 32- bit integer
Blemish Min Edge Length 32- bit integer
Blemish Min Edge Length 32- bit integer
Table 17: Match Sensor Type ID = 4
Sensor Specific Data Sensor Location
Match Count 32- bit integer
Match Min Percent 16- bit integer
Match Max Percent 16- bit integer
Table 18: Sort Sensor Type ID = 5
Sensor Specific Data Sensor Location
Sort Pattern Map 16-bit integer
Sort Pattern Count 16-bit integer
Sort Pattern 1 Count 16-bit integer
Sort Pattern 2 Count 16-bit integer
Sort Pattern 3 Count 16-bit integer
Sort Pattern 4 Count 16-bit integer
Sort Pattern 5 Count 16-bit integer
Sort Pattern 6 Count 16-bit integer
Sort Pattern 7 Count 16-bit integer
Sort Pattern 8 Count 16-bit integer
Sort Pattern 9 Count 16-bit integer
Sort Pattern 10 Count 16-bit integer
Sort Min Percent Match 16-bit integer
Sort Max Percent Match 16-bit integer
Custom Map
Main Menu
> System > Communications > Industrial EtherNet > Map > Custom
iVu Plus TG Gen2 Image Sensor
112 www.bannerengineering.com - Tel: 763.544.3164