7.2 Configuring an Area Sensor
NOTE: By default, the Trigger
is set to Internal, and will continuously trigger based on a time interval
setting. This may make it more difficult to make adjustments while setting up the sensor. The best
practice is as follows:
Go to the Main Menu > Imager > Trigger menu and select External.
Make sure there is no external trigger input.
Use the Trigger icon in the lower-right of the screen to manually trigger the sensor to capture
an image as you set up and test.
Capture images of a range of samples to set up from the "worst" good part to the "best" bad
part.
Start the setup with a good part. Normally, each part to be tested will be centered in the Field of View (FOV).
To adjust the Region of Interest (ROI), follow the steps listed here.
The ROI is the red box as shown.
1.
Click anywhere within the ROI to select it. When selected, the ROI has resize and rotational icons in the corners. It
also changes the top button to the sensor name of the selected ROI.
iVu Plus TG Gen2 Image Sensor