4. Write. IP address of the iVu Plus is entered here.
9.6.2 Inputs to iVu (Outputs from PLC)
The registers below are used by the PLC to push values to the iVu Plus sensor. MSG (message) commands are used to
write (N14) to the sensor.
Table 33: PCCC PLC Output Registers (iVu Plus Inputs, N14 Table)
WORD # WORD NAME DATA TYPE
0 Input Bits Register (see Input and Output Flags on page
144) 16-bit integer
1-2 Product Change Number 32-bit integer
3-49 reserved 32-bit integer
50 Command ID 16-bit integer
51 Command Parameter Int16 16-bit integer
52-53 Command Parameter Int 32 32-bit integer
54-55 Command Parameter Float
56-57 Command Parameter String Length 32-bit integer
58-107 Command Parameter String 100 Byte Array
108 reserved 16-bit integer
109-110 BCR String/Mask Length 32-bit integer
111-120 BCR String/Mask 200 Byte Array
211-239 reserved 16-bit integer
9.6.3 Outputs from iVu (Inputs to PLC)
The registers below are used to send output values from the iVu Plus to the PLC. MSG (message) commands are used to
read (N7) from the sensor.
9.6.4 Multiple Sensors Mapping Options
When using an iVu Plus TG with multiple sensors in an inspection, there are two mapping options: Default and Custom.
iVu Plus TG Gen2 Image Sensor