System Command Group
Command Group Item Description
Do System Reboot Reboots the sensor. Pre-empts other commands except Save.
Do System Save Saves inspection and configuration parameters. Blocks until finished.
Should be used sparingly.
Get Ethernet IPAddress Get the current active IP address of the sensor as a string.
Get Ethernet SubnetMask Get the current active subnet mask of the sensor as a string.
Get Ethernet Gateway Get the current active Gateway address of the sensor as a string.
Set Ethernet IPAddress Set IP address of the sensor. A valid IP address must be supplied as a
string (for example: 192.168.0.1). A 'Reboot' command from the
command channel must follow in order to make the new IP address
effective. You may also set new Subnet Mask and Gateway address as
required before a 'Reboot' command is sent to the sensor.
Set Ethernet SubnetMask Set new subnet mask. A 'Reboot' command is required to be sent from
the command channel in order to make the new mask effective.
Set Ethernet Gateway Set new Gateway IP address. A 'Reboot' command is required to be
sent from the command channel to make the new address effective.
Examples
>> do system save\x0D\x0A
<< OK\x0D\x0A
Status Command Group
Command Group Item Description
Get Status Ready Flag indicating whether the system is ready to trigger (true) or busy
(false).
Get Status SystemError Flag indicating whether a system error is active (true) or cleared
(false).
Do Status ClearSystemError Clears the system error LED and sets the internal flag to false.
Examples
>> get status ready\x0D\x0A
<< OK\x0D\x0A
<< True\x0D\x0A
>> get status systemerror\x0D\x0A
<< OK\x0D\x0A
<< False\x0D\x0A
>> do status clearsystemerror\x0D\x0A
<< OK\x0D\x0A
Trigger Command Group
Command Group Item Description
Get Trigger Mode Sets trigger mode to one of the valid trigger modes for the sensor.
Set Trigger Mode Sets trigger mode to one of the valid trigger modes for the sensor.
Do Trigger Initiates a single trigger. The sensor does not transmit a response until
the sensor has completed the action.
iVu Plus TG Gen2 Image Sensor
92 www.bannerengineering.com - Tel: 763.544.3164