7.5 Configuring a Sort Application
NOTE: By default, the Trigger is set to Internal, and will continuously trigger based on a time interval
setting. This may make it more difficult to make adjustments while setting up the sensor. The best
practice is as follows:
•
Go to the Main Menu > Imager > Trigger menu and select External.
•
Make sure there is no external trigger input.
• Use the Trigger icon in the lower-right of the screen to manually trigger the sensor to capture
an image as you set up and test.
• Capture images of a range of samples to set up from the "worst" good part to the "best" bad
part.
1. Make sure you use good parts for the inspection setup. Normally, each part will be centered in the field of view
with the feature of interest surrounded by the Region of Interest (ROI).
For the first part, select the ROI by clicking inside it. Move it, resize it, and rotate it by dragging the ROI or its
corners. Once the feature of interest is within the ROI, click the Teach button. The feature will be highlighted in
green.
2.
Click the Save button to save the pattern to the first empty pattern storage slot.
3.
Set match criteria:
iVu Plus TG Gen2 Image Sensor