The Percent Match setting adjusts for how closely the inspected part or label matches the reference part or label. The
Percent Match scale is from 0 to 100 where 0 is the most tolerant and 100 is the least tolerant. Move the slider to the left
or to the right.
Rotation Range
Main Menu > Inspection > Sensors > Sort > Rotation Range
The Rotation Range
sets the expected rotation of parts or labels during an inspection. For example, a value of 45 means
that the part may rotate 45 degrees in either direction from the reference part and still pass. Move the slider from 0 to 180
degrees.
NOTE: The smaller the rotation range, the faster the inspection will run.
Pass Criteria
Main Menu > Inspection >Sensors > Sort > Pass Criteria
There are four options to select from to define pass criteria for a Sort sensor inspection, which are described below using
an example where there are two saved patterns.
•
Any Saved Pattern—Pass condition if the sensor matches either Pattern_1, Pattern_2, or both
• All Saved Patterns—Pass condition if the sensor matches both Pattern_1 AND Pattern_2
• Single Saved Pattern—Pass condition if the sensor matches either Pattern_1 OR Pattern_2, but NOT both
• Specific Saved Pattern (requires selecting a saved pattern to match; for example, Pattern_2) - Pass condition when
the sensor matches only Pattern_2
Timeout
Main Menu > Inspection > Sensors > Sort > Timeout
When the sensor type is set as Match or Sort, this screen provides for adjusting the maximum time the inspection is
allowed to execute. A timeout error is reported in the case inspection runs out of time. If this value is set too high, the
sensor can miss triggers while trying to detect a bad pattern.
5.2.2 Motion Menu
Main Menu > Inspection > Motion
Enable Motion when the part is expected to move or rotate. Motion settings also involve selecting the number of edges to
locate, adjusting sensitivity, and selecting whether or not rotation is enabled. These settings appear on the Inspection
Menu after Motion is set to 'Enabled'. Motion is enabled when Area and/or Blemish sensor are included in the inspection.
Number of Edges
Main Menu > Inspection > Motion > Number of Edges
On the Number of Edges
screen, use the radio buttons to select One Edge or Two Edges. If One Edge is selected, motion is
tracked in one direction (by default, horizontally); if Two Edges is selected, motion can be tracked horizontally and
vertically.
iVu Plus TG Gen2 Image Sensor
www.bannerengineering.com - Tel: 763.544.3164 29