EasyManua.ls Logo

Banner iVu Plus TG Gen2 - 6 Setting Up and Configuring Inspections; 6.1 Acquiring a Good Image

Banner iVu Plus TG Gen2
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Setting up an Inspection
The device holds up to 30 inspections. Inspections may hold multiple sensors.
To set up for an inspection:
1.
Acquire a good image.
2. Configure the sensor(s) in the inspection
3. Configure multiple sensors in the inspection
6.1 Acquiring a Good Image
The iVu Series sensor needs to capture a good image of each part to ensure that it correctly passes good parts and fails
bad parts.
1.
Go to Main Menu > Imager > Auto Exposure to run the Auto Exposure routine.
2. Check the lighting.
Make sure that the lighting is constant and consistent (unchanging over time, no shadows or hot spots).
Capture the shape and form of the target object with lighting that optimizes its contrast and separates it
from the background. Depending on the target, this may mean the integral ring light is not the best choice
and other Banner lights should be considered.
Adjust the mounting angle to provide the clearest image of the part features you are monitoring. The
mounting bracket lets you easily position and adjust the sensor on your line.
3. If needed, go to Main Menu > Imager > Auto Exposure to run the Auto Exposure routine a second time or
adjust Gain and Exposure manually:
Main Menu > Imager > Gain
Main Menu > Imager
> Exposure
4.
Go to Main Menu > Imager > Focus to adjust the focus while monitoring the Focus Number:
iVu Plus TG Gen2 Image Sensor
56 www.bannerengineering.com - Tel: 763.544.3164

Table of Contents