7.4 Configuring a Match Sensor
NOTE: By default, the Trigger is set to Internal, and will continuously trigger based on a time interval
setting. This may make it more difficult to make adjustments while setting up the sensor. The best
practice is as follows:
Go to the Main Menu > Imager > Trigger menu and select External.
Make sure there is no external trigger input.
Use the Trigger icon in the lower-right of the screen to manually trigger the sensor to capture
an image as you set up and test.
Capture images of a range of samples to set up from the "worst" good part to the "best" bad
part.
Start the setup with a good part. Normally, each part to be tested will be centered in the Field of View (FOV).
Teach the sensor a good reference part.
1.
Adjust the Region of Interest (ROI).The ROI is a dotted box as shown.
2.
Click Anywhere within the ROI to select it. When selected, the ROI is bolded with resize and rotational icons in the
corners.
3.
Resize the ROI so that it surrounds just the feature of interest. In the Demo example, the feature of interest is the
Banner logo.