EasyManua.ls Logo

Banner iVu Plus TG Gen2 - PLC5 and SLC 5 (PCCC); Configuration

Banner iVu Plus TG Gen2
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9.6 PLC5 and SLC 5 (PCCC)
Allen-Bradley’s PLC5 and SLC 500 family of devices use PCCC communications protocol. iVu Plus supports these PLCs using
input and output register arrays. The Output Flags, ACK Flags and Input Flags bit definitions are the same as defined in the
EIP Assembly Objects section. The terms “Input” and “Output” are from the point of view of the PLC.
9.6.1 Configuration
The images below represent a typical configuration.
1.
Read. In the below example, message command reading from N7 table on iVu Plus and sending the data to the N7
table on the PLC.
iVu Plus TG Gen2 Image Sensor
www.bannerengineering.com - Tel: 763.544.3164 137