9.7.2 iVu PROFINET IO Data Model
The PROFINET IO data model is based on the typical, expandable field device that has a backplane with slots. Modules and
submodules have different functionalities. Modules are plugged into slots; submodules are plugged into subslots. In the
PROFINET IO data model, Slot 0 Subslot 1 is reserved for the Device Access Point (DAP) or network interface.
Both modules and submodules are used to control the type and volume of data that is sent to the controller (PLC).
A submodule is typically designated as input type, output type, or combined input/output type.
An input submodule is used to send data to the controller (PLC).
An output submodule is used to receive data from the controller (PLC).
The combined input/output submodule simultaneously receives and sends data in both directions.
Configuring the iVu for a PROFINET IO Connection
The iVu Plus TG device and the controller (PLC) must be configured for PROFINET
®
.
1. Click on the Wrench button on the iVu Plus Home screen.
The Main Menu window displays.
2.
Click on System and scroll down to Communications.
iVu Plus TG Gen2 Image Sensor