7.8 Configuring a Mask
A mask created for a sensor will not apply to any other sensors in the inspection. The mask ROI type can be rectangular,
elliptical, or circular. Use up to ten masks per sensor.
1.
Select the desired ROI. When selected, the ROI has resize and rotational icons in the corners.
2. Click the sensor name button to open the sensor parameters menu.
3.
Select ROI and Mask.
4. Select the Enable Mask checkbox.
5.
Click
to return to the home screen.
6.
Re-select the ROI from step 1.
7. Press
to insert the mask. The mask displays in blue with a diagonal line pattern in the region.
8. To change the shape of the mask ROI, press , , and to cycle through the shape options.
9.
Adjust the mask ROI as appropriate for the application.