Command Group Item Description
Get MATCH_HISTORY MaxPercent The maximum detected match percentage, since history was last
cleared.
Examples
>> get match_history count\x0D\x0A
<< OK\x0D\x0A
<< 1\x0D\x0A
>> get match_history maxcount\x0D\x0A
<< OK\x0D\x0A
<< 6\x0D\x0A
SORT_RESULT Command Group
Command Group Item Description
Get SORT_RESULT Count The number of detected sort patterns.
Get SORT_RESULT MinPercentMatch The minimum detected sort pattern match percentage.
Get SORT_RESULT MaxPercentMatch The maximum detected sort pattern match percentage.
Get SORT_RESULT PatternNumbers Listing of detected patterns by pattern number.
Get SORT_RESULT PatternNames Listing of detected patterns by pattern name.
SORT_HISTORY Command Group
Command Group Item Description
Get SORT_HISTORY MinCount The minimum number of detected sort patterns, since history was last
cleared.
Get SORT_HISTORY MaxCount The maximum number of detected sort patterns, since history was last
cleared.
Get SORT_HISTORY MinPercent The minimum detected sort pattern match percentage, since history
was last cleared.
Get SORT_HISTORY MaxPercent The maximum detected sort pattern match percentage, since history
was last cleared.
Examples
>> get sort_history mincount\x0D\x0A
<< OK\x0D\x0A
<< 1\x0D\x0A
>> get sort_history maxcount\x0D\x0A
<< OK\x0D\x0A
<< 6\x0D\x0A
8.4.5
Multiple Sensors Inspection
When having more than one sensor in the inspection, all SensorType_Result and SensorType_History related commands
must include the Sensor Name in "< >" brackets.
Examples
>> get area_result <Area1> count\x0D\x0A
<< OK\x0D\x0A
<< 7665\x0D\x0A
iVu Plus TG Gen2 Image Sensor
www.bannerengineering.com - Tel: 763.544.3164 97