EasyManua.ls Logo

Banner iVu Plus TG Gen2 - Page 140

Banner iVu Plus TG Gen2
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Default Map
Main Menu
> System > Communications > Industrial EtherNet > Map > Default
Automatically maps sensor data for each inspection. Recommended when execution order of sensor types is the same
across inspections. When inspection has multiple sensors, the first 5 sensor results will be shown starting at offset 55.
Each sensor result will occupy 20 words.
Table 34: PCCC PLC Input Registers (iVu Plus Outputs, N7 Table): DEFAULT MAP
WORD # WORD NAME Data Type
0 Input Bits ACK Register (see Input and Output Flags on page
144) 16-bit integer
1 Output Bits Register (see Input and Output Flags on page 144) 16-bit integer
2-3 Error Code 32-bit integer
4-5 Inspection Number 32-bit integer
6-7 Iteration Count 32-bit integer
8-9 Pass Count 32-bit integer
10-11 Fail Count 32-bit integer
12-13 Missed Triggers 32-bit integer
14-15 Current Inspection Time Float
16 Sensor Pass/Fail Coil 16-bit integer
17-29 reserved 16-bit integer
30-52 Inspection Name 2-Word Length + 20-Unicode chars
53-54 Frame Number 32-bit integer
55 Sensor Type ID (Sensor 1) 16-bit integer
56-74 Sensor 1 Specific Data 16-bit integer
75 Sensor Type ID (Sensor 2) 16-bit integer
76-89 Sensor 2 Specific Data 16-bit integer
95 Sensor Type ID (Sensor 3) 16-bit integer
95-114 Sensor 3 Specific Data 16-bit integer
115 Sensor Type ID (Sensor 4) 16-bit integer
116-134 Sensor 4 Specific Data 16-bit integer
135 Sensor Type ID (Sensor 5) 16-bit integer
136-154 Sensor 5 Specific Data 16-bit integer
155-170 reserved 16-bit integer
171 Command Status 16-bit integer
172 Command Response Int16 16-bit integer
173-174 Command Response Int32 32-bit integer
175-176 Command Response Float Float
177-178 Command Response Length 32-bit integer
179-228 Command Response Data 100 Byte Array
229-239 reserved 16-bit integer
NOTE: If the inspection contains more than 5 sensors, the sensor after the 5th one will not be on the
map.
Table 35: Area Sensor Type ID = 2
Sensor Specific Data Data Size
Area Count 32- bit integer
Area Range Min 32- bit integer
Area Range Max 32- bit integer
iVu Plus TG Gen2 Image Sensor