Table 36: Blemish Sensor Type ID = 3
Sensor Specific Data Sensor Location
Blemish Count 32- bit integer
Blemish Min Edge Length 32- bit integer
Blemish Min Edge Length 32- bit integer
Table 37: Match Sensor Type ID = 4
Sensor Specific Data Sensor Location
Match Count 32- bit integer
Match Min Percent 16- bit integer
Match Max Percent 16- bit integer
Table 38: Sort Sensor Type ID = 5
Sensor Specific Data Sensor Location
Sort Pattern Map 16-bit integer
Sort Pattern Count 16-bit integer
Sort Pattern 1 Count 16-bit integer
Sort Pattern 2 Count 16-bit integer
Sort Pattern 3 Count 16-bit integer
Sort Pattern 4 Count 16-bit integer
Sort Pattern 5 Count 16-bit integer
Sort Pattern 6 Count 16-bit integer
Sort Pattern 7 Count 16-bit integer
Sort Pattern 8 Count 16-bit integer
Sort Pattern 9 Count 16-bit integer
Sort Pattern 10 Count 16-bit integer
Sort Min Percent Match 16-bit integer
Sort Max Percent Match 16-bit integer
Custom Map
Main Menu
> System > Communications > Industrial EtherNet > Map > Custom
The custom maps allows customization of fix sensor data on the map by selecting data items of interest for each sensor
type. This is recommended when the execution order of sensor types vary across inspections or when using more than five
sensors.
A system-level custom map is supported for additional flexibility. When the custom map is selected, a customizable space
is used in the offset range (55 to 166) on PCCC registers.
Table 39: PCCC PLC Input Registers (iVu Plus Outputs, N7 Table): CUSTOM MAP
WORD # WORD NAME Data Type
0 Input Bits ACK Register (see Input and Output Flags on page
144) 16-bit integer
1 Output Bits Register (see Input and Output Flags on page 144) 16-bit integer
2-3 Error Code 32-bit integer
4-5 Inspection Number 32-bit integer
6-7 Iteration Count 32-bit integer
8-9 Pass Count 32-bit integer
10-11 Fail Count 32-bit integer
iVu Plus TG Gen2 Image Sensor
www.bannerengineering.com - Tel: 763.544.3164 141