WORD # WORD NAME Data Type
12-13 Missed Triggers 32-bit integer
14-15 Current Inspection Time Float
16 Sensor Pass/Fail Coil 16-bit integer
17-29 reserved 16-bit integer
30-52 Inspection Name 2-Word Length + 20-unicode chars
53-54 Frame Number 32-bit integer
55-166 Customizable Space (112 reg) 16-bit integer
167-170 reserved 16-bit integer
171 Command Status 16-bit integer
172 Command Response Int16 16-bit integer
173-174 Command Response Int32 32-bit integer
175-176 Command Response Float Float
177-178 Command Response Length 32-bit integer
179-228 Command Response Data 100 Byte Array
229-239 reserved 16-bit integer
Configure Custom Industrial Ethernet (IE) Map
Enable the Custom Map by selecting Custom on the drop-down list.
Click on the yellow arrow button to access the Custom IE Map
screen. The Custom IE Map screen allows choosing
sensor result data that appears on the customizable space.
iVu Plus TG Gen2 Image Sensor
142 www.bannerengineering.com - Tel: 763.544.3164