4. Double-click on the Hardware icon in the Station level
window to open the Hardware configuration window.
5.
Right-click on the PN-IO line in the CPU module of the Station window and select Insert PROFINET IO System.
6. In the Parameters tab of the Ethernet interface properties window type in the IP Address and Subnet Mask of the
PLC.
7. Select the Ethernet subnetwork from the box at the bottom of the Ethernet interface properties window. If no
suitable network is shown, click the New button to add one, then click OK.
8.
Click iVu Plus TG in the Hardware catalog and drag and drop onto the PROFINET IO system connection.
The device is connected to the system.
9.
Add modules and submodules.
Changing the Device IP Address
Use these instructions for the Siemens SIMATIC STEP 7 (v5.5) software.
1. Start Siemens SIMATIC Manager.
2. Select an existing project and open it.
iVu Plus TG Gen2 Image Sensor
172 www.bannerengineering.com - Tel: 763.544.3164