EasyManua.ls Logo

Banner iVu Plus TG Gen2 - Page 197

Banner iVu Plus TG Gen2
208 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. Verify that the Execution Error flag is not set (i.e. value should be 0). This is bit 15 in the Output Bits/Status Coil
Bits register. If the value is 1, read the Error Code
register for more information.
6. Task Complete. Toggle the Command bit back to 0 (bit 15 in the Input Bits/Input Coil Bits register). The new
exposure time will be used for the next inspection. Please note that this value is not saved to the iVu's permanent
memory unless the Save Configuration task is completed.
Save iVu Configuration
This command saves all modified inspection and configuration parameters to the iVu Plus, including Command Channel
changes to exposure time and gain, trigger mode, barcode compare string and/or mask, and Remote Teach sessions.
1. Write the number 102 as a 16-bit integer into the Command ID register.
2. Toggle the Command bit from 0 to 1 (bit 15 in the Input Bits/Input Coil Bits register).
3. Wait for the Command ACK flag to go from 0 to 1 (bit 15 in the Input Bits ACK/Input Coil Bits ACK register).
4. Verify that the Execution Error flag is not set (i.e. value should be 0). This is bit 15 in the Output Bits/Status Coil
Bits register. If the value is 1, read the Error Code register for more information.
5. Task Complete. Toggle the Command bit back to 0 (bit 15 in the Input Bits/Input Coil Bits register).
iVu Plus TG Gen2 Image Sensor
www.bannerengineering.com - Tel: 763.544.3164 197

Table of Contents

Related product manuals